1. Protocol Introduction
OPC UA (OPC Unified Architecture) is a machine-to-machine communication protocol for industrial automation, maintained by the OPC Foundation. It provides a unified information model, extensible data type system, and built-in security mechanisms (Certificate, Encryption, Signing).
2. Configuration Model
2.1 Channel Configuration
Channel is the OPC UA session boundary: One Channel corresponds to one OPC UA Server (or one endpoint).
2.1.1 Application Identity
applicationName: Client Application Name (Required)applicationUri: Client Application URI (Required)
These fields participate in UA's application description and certificate/trust chain system (especially in certificate authentication mode).
2.1.2 url (Endpoint URL)
Example
opc.tcp://192.168.1.10:4840opc.tcp://server-hostname:4840
2.1.3 auth.kind (Authentication Mode)
- anonymous: Anonymous (Most common)
- userPassword: Username and Password
- issuedToken: Issued Token (Token string)
- certificate: Certificate mode (
privateKey+certificate)
Note
Certificate content is usually stored as PEM string.
2.1.4 Security Policy & Security Mode
securityPolicy: e.g., None / Basic256Sha256 / Aes256Sha256RsaPss ...securityMode: None / Sign / SignAndEncrypt
Best Practice
- Production environment recommends at least
Sign, preferablySignAndEncrypt. - If Server only opens certain policy/mode combinations, please align with Server's endpoint configuration.
2.1.5 Collection Mode: readMode
- Subscribe: Driver creates Subscription + MonitoredItems, Server pushes changes (Recommended).
- Read: Active Read by collection period (Suitable for few points or Server does not support subscription/limits subscription).
Note
Subscribe mode is more "Event Driven", more efficient for high-frequency changing points, but pay attention to subscription batch and keep-alive parameters.
2.1.6 Session & Keep-Alive Parameters
sessionTimeout: Session timeout (ms, default 30000)keepAliveInterval: Keep-alive interval (ms, default 30000)maxFailedKeepAliveCount: Max failed keep-alive count (Default 3)subscribeBatchSize: Subscription batch size (Default 256)
Tuning Suggestion
- When there are many points, appropriately increasing
subscribeBatchSizecan reduce create/modify request times, but too large may trigger server-side limits. keepAliveIntervalshould not be too small (increases Server pressure), nor too large (slow fault detection); default value is usually a reasonable starting point.
2.2 Device Configuration
OPC UA driver's device driver configuration is empty.
Modeling Suggestion
- You can model "A production line/A section/A subsystem" as a Device for organizing points and northward topic routing.
Grouped collection
When OPC UA uses Read (Periodic Collection) mode, and there are multiple business Devices under the same Channel, OPC UA driver will enable grouped collection: Collector will merge points of these Devices into one collect_data(items) call, driver will merge NodeIds for one batch Read, then split into respective NorthwardData outputs by device_id.
2.3 Point Configuration
nodeId: OPC UA NodeId string
2.4 Action Configuration
Action is used to encapsulate a set of "Write Node" operations; Action itself does not carry protocol detail configuration.
- Key Semantics: OPC UA write target NodeId should be configured on Action's
inputs(Parameter), i.e., each parameter specifies the NodeId to write viaParameter.driver_config.nodeId.
Parameter-level driver configuration fields (Each input parameter):
nodeId: OPC UA NodeId string
TIP
For NodeId format and selection method, see NodeId Syntax.
3. Data Type Mapping Table
3.0 Recommended Mapping Table
| UA Variant (Scalar) | Recommended DataType | Description |
|---|---|---|
| Boolean | Boolean | - |
| SByte/Byte | Int8/UInt8 | - |
| Int16/UInt16 | Int16/UInt16 | - |
| Int32/UInt32 | Int32/UInt32 | - |
| Int64/UInt64 | Int64/UInt64 | - |
| Float/Double | Float32/Float64 | - |
| String | String | Can also map to Timestamp (RFC3339) or Binary (hex string) |
| ByteString | Binary | - |
| DateTime | Timestamp | Timestamp semantics is i64 milliseconds |
3.1 Read Path
- Numeric Variant (
SByte/Int16/Int32/Int64/Float/Double etc.):- First decode by wire data type, then convert wire→logical by logical data type + Transform.
Variant::Boolean: Same as above (Recommend logical asBoolean, avoid non-numeric mapping restrictions).Variant::String:DataType::String: Output string directly.DataType::Timestamp: Try parsing RFC3339.DataType::Binary: Try parsing hex string.
Variant::ByteString: Recommend mapping toBinary.Variant::DateTime: Recommend mapping toTimestamporString.Variant::Array: Not supported in current version, returns empty (Point will not produce value).
Important
If you need array/structure, suggest providing scalar nodes on Server side, or extending "Structure/Array" to JSON mapping capability on edge side.
3.2 Write Path
When writing, force convert according to Point's data_type and generate Variant; Timestamp will be converted to UA DateTime (Write fails if timestamp is invalid).
Best Practice
- Try to keep Point/Parameter
data_typeconsistent with Server node's real type, avoiding precision/range issues caused by implicit conversion. - If Server node is array/structure: Suggest providing scalar nodes on Server side, or extending "Structure/Array → JSON" capability on edge side; current version does not output array values.